Duplex ASTM A815 S32205 2205 Tampa final do tubo

SKU: SASA-S32205-CAP-B169 Categorias: ,

Dúplex 2205 butt-weld end cap combining higher strength with resistance to chloride stress-corrosion cracking and localized corrosion for demanding process piping.

  • ✓Material: ASTM A815, EUA S32205 / Dúplex 2205 / EN 1.4462
  • ✓Padrão: ASME B16.9 dimensions
  • ✓Faixa: NPS 1/2–48; schedules subject to manufacturing review
  • ✓Documentos: EN 10204 3.1, PMI and heat-treatment records as ordered

Descrição

Encaixe de tubo para soldagem de topo feito de fábrica

ASTM A815 S32205 Duplex 2205 Tampa final do tubo

A high-strength duplex stainless steel butt-weld closure for offshore, dessalinização, químico, marine and pulp-and-paper piping.

O que é um ASTM A815 S32205 Duplex 2205 tampa de tubo?

Um ASTM A815 S32205 pipe end cap is a wrought duplex stainless steel butt-welding fitting used to terminate a pipe or header. Its ferritic-austenitic microstructure gives Duplex 2205 a combination of strength and corrosion resistance that can outperform conventional austenitic stainless steels in suitable chloride-bearing services.

Correct solution heat treatment and controlled fabrication are essential to the intended duplex phase balance and corrosion performance. Purchase specifications should define the exact ASTM A815 grade designation, Número UNS, tratamento térmico, testing and any project-specific ferrite or corrosion-test acceptance criteria.

Maior resistênciaOften permits efficient component design compared with common austenitic stainless grades.
Chloride SCC resistanceOffers improved resistance to chloride stress-corrosion cracking in many environments.
Localized corrosion performanceA strong option for appropriate marine, brackish-water and process duties.
Controlled metallurgyTratamento térmico, PMI and traceability support project-specific acceptance.

S32205 Duplex 2205 cap specifications

Tipo de produto Duplex stainless steel butt weld pipe end cap
Especificação de materiais ASTM A815, ordered grade designation with UNS S32205
Designação de materiais UNS S32205 / Dúplex 2205; comumente referenciado com EN 1.4462
Padrão dimensional ASME B16.9
Tamanho nominal NPS 1/2–48 / DN15–DN1200, sujeito à parede e rota de fabricação
Espessura da parede Standard schedules and custom walls subject to forming and heat-treatment review
Construção Sem costura ou soldado conforme aplicável e solicitado
Tratamento térmico Solution heat treated in accordance with the ordered material specification
Preparação final Butt-weld bevel to the matching pipe and welding specification
Documentação EN 10204 3.1 CTM, PMI, heat-treatment record and additional testing as ordered

Dimensões e tolerâncias seguem padrão e edição solicitada. A adequação final da pressão-temperatura é determinada pelo código de projeto da tubulação, material, espessura da parede, condições de tubulação e serviço correspondentes.

Requisitos ASME e projetos europeus

Projetos norte-americanos

Especificar ASTM A815 with the complete grade designation and UNS S32205, ASME B16.9, NPS, cronograma de parede, construção, supplementary tests and required solution heat-treatment records.

Projetos europeus

Specify EN 1.4462 onde necessário, together with DN, espessura da parede, padrão dimensional, inspection certificate, regulatory requirements and any corrosion or ferrite testing.

Nota de aquisição: As designações ASTM/ASME e EN não são automaticamente intercambiáveis. Indique a especificação do material necessário, padrão dimensional, edição, espessura da parede e critérios de aceitação no pedido de compra.

Dúplex 2205 vs 316L pipe end cap

Ponto de seleção S32205 Duplex 2205 WP316L / S31603
Structure Duplex ferritic-austenitic Austenítico
Força Higher typical yield strength Lower typical yield strength but broad fabrication familiarity
Chloride behavior Improved SCC and localized corrosion resistance in many services Good general resistance; limitations increase with severe chloride exposure
Controle de fabricação Tighter heat-input and phase-balance control Established austenitic stainless welding practice

Aplicações típicas

Indústria Serviço típico Motivo da seleção
Petróleo e gás offshore Água produzida, utilities and process headers Strength and chloride resistance
Dessalinização Pretreatment, brackish water and selected seawater systems Resistance to localized corrosion when correctly specified
Processamento químico Chloride-bearing and corrosive process lines Balanced strength and corrosion performance
Celulose e papel Bleaching and chemical-recovery support systems Useful resistance in selected chloride and chemical environments

Exemplos de aplicação são apenas para orientação. O engenheiro do projeto deve confirmar a compatibilidade do material, tolerância à corrosão, requisitos de impacto e conformidade com o código de design.

Fabricação, inspeção e documentação

Duplex fittings require disciplined forming, welding where applicable and solution heat treatment. PMI, registros de tratamento térmico, ferrite testing and corrosion testing can be incorporated into the inspection plan when the project specification requires them.

Identidade material
PMI and heat-number traceability confirm the ordered UNS designation.
Tratamento térmico
Solution heat-treatment cycle and records reviewed against ASTM A815 requisitos.
Duplex controls
Ferrite, dureza, corrosion or NDE testing performed when specified.
Dimensional release
Tamanho, parede, comprimento, ovality and bevel verified before export packing.

Lista de verificação de RFQ

  1. Classe do material e especificação do produto
  2. Padrão dimensional e edição
  3. Tamanho NPS ou DN
  4. Programação do tubo ou espessura exata da parede
  5. Construção sem costura ou soldada, quando necessário
  6. Preparação final e detalhe do chanfro
  7. Quantidade e destino de entrega
  8. CTM, Requisitos de inspeção NDE e de terceiros

Perguntas frequentes

Is S32205 the same as Duplex 2205?

UNS S32205 is a widely specified Duplex 2205 composition with defined chemistry controls. The full ordered material standard and grade designation remain authoritative.

Why choose Duplex 2205 instead of 316L?

Dúplex 2205 offers higher strength and improved resistance to chloride stress-corrosion cracking and localized corrosion in many services, but it also needs tighter welding and heat-treatment control.

Is a ferrite test required?

It is not automatically required for every order in the same way. If the project has a ferrite acceptance range or test method, include it in the purchase specification.

Can S32205 caps be welded to duplex pipe?

Sim, when the pipe, metal de adição, procedimento de soldagem, heat input and interpass temperature are properly specified and qualified by the fabricator.

What should be included in the RFQ?

Include ASTM A815 nota, UNS S32205, ASME B16.9, tamanho, parede, construção, tratamento térmico, EQM, ferrite or corrosion tests and certification requirements.

Solicite um Duplex 2205 pipe cap quotation

Share the full grade designation, tamanho, parede, quantity and duplex inspection plan for a technically matched offer.

Solicite um orçamentoVeja as tampas das extremidades dos tubos


Deixe sua mensagem

    Envie seu tamanho, material, padrão e quantidade. Responderemos dentro 24 horas.

    Carregar imagem / Desenho (opcional)

    Aceito: JPG, png, WebP ou PDF. Tamanho máximo do arquivo: 5 MB.