説明
Duplex stainless steel industrial valve
二重 2205 スイングチェックバルブ
A high-strength chloride-resistant valve material for offshore, 化学薬品, pulp and water applications. The swing check valve configuration is engineered for backflow prevention in steady-flow process and utility lines.
What is a Duplex 2205 スイングチェックバルブ?
A Duplex 2205 Swing Check Valve combines a ferritic-austenitic duplex stainless steel combining higher strength with improved chloride stress-corrosion and localized-corrosion resistance compared with common austenitic grades with an automatic non-return design whose hinged disc opens with forward flow and closes as flow decelerates or reverses.
Duplex performance depends on balanced microstructure, correct solution heat treatment, controlled welding and component-specific material specifications. Check valves should be sized from minimum, normal and maximum flow plus transient behavior rather than automatically matching the pipe size.
二重 2205 Swing Check Valve specifications
| 製品 | 二重 2205 スイングチェックバルブ |
|---|---|
| Valve construction | Bolted-cover swing check valve with hinged disc and service-specific seat/hinge arrangement |
| Nominal material | 二重 2205 |
| 私たち / EN reference | UNS S32205/S31803; EN 1.4462 |
| Product forms | Wrought ASTM A182 F60/F51; cast ASTM A995/A890 4A where applicable; heat treatment and corrosion testing defined by order |
| Design standards | API 594 そして ASME B16.34; API 6D only for specifically designed pipeline-service valves |
| Pressure testing | API 598 or project-specified shell and closure testing |
| 圧力定格 | ASME Class or PN rating verified against exact material, サイズ, construction and design temperature |
| End connections | RF/RTJ flanged or butt-weld ends according to design |
| Operation | Automatic; external lever/weight, spring assist or dashpot only when engineered |
| ドキュメント | EN 10204 3.1 material records, pressure test report, GA drawing and project inspection records as ordered |
This is an engineered inquiry product, not a universal stock specification. Final availability depends on valve size, 圧力クラス, material form, trim, seat system, operator, quantity and required code edition.
二重 2205 material selection
| 選定のポイント | Engineering guidance |
|---|---|
| Material profile | a ferritic-austenitic duplex stainless steel combining higher strength with improved chloride stress-corrosion and localized-corrosion resistance compared with common austenitic grades |
| Why it is selected | Higher strength than 300-series stainless steels with useful pitting, crevice and chloride stress-corrosion resistance. |
| 代表的なサービス | Offshore production, produced water, パルプと紙, chemical processing and chloride-bearing water systems. |
| Limitations to check | 温度制限, hydrogen-related damage, improper heat treatment and intermetallic phases must be considered. 2205 is not interchangeable with super duplex 2507. |
| Specification route | Wrought ASTM A182 F60/F51; cast ASTM A995/A890 4A where applicable; heat treatment and corrosion testing defined by order |
| Verification | PMI, MTC, heat treatment records and specified ferrite, ASTM A923 or corrosion testing according to the project material specification. |
Swing Check Valve design and standards
API 594
Common design and testing basis for check valves within its scope.
ASME B16.34
圧力-温度, material and general valve design requirements within scope.
API 598
Shell and closure pressure-testing basis when specified.
API 6D
Pipeline-service requirements apply only to valves specifically designed and documented to API 6D.
Disc stability, minimum velocity, pressure drop, orientation, pump trip and system transients affect slam risk and service life.
Fire-safe, fugitive-emission, sour-service, oxygen, cryogenic, chlorine and PED requirements apply only when explicitly defined and supported for the exact offered configuration.
代表的な用途
| 業界 | Material service context | Valve selection focus |
|---|---|---|
| 海洋石油とガス | Produced water, utility and selected process systems | Minimum stable velocity, orientation, pressure drop, disc dynamics, closure leakage and transient control |
| Pulp and paper | Digesters, bleaching support and chloride-bearing process lines | Minimum stable velocity, orientation, pressure drop, disc dynamics, closure leakage and transient control |
| 化学処理 | Organic acids, chlorides and mixed process streams after review | Minimum stable velocity, orientation, pressure drop, disc dynamics, closure leakage and transient control |
| Water and desalination | Feed, pretreatment and moderate seawater-related systems | Minimum stable velocity, orientation, pressure drop, disc dynamics, closure leakage and transient control |
Application examples are not a corrosion or design approval. The end user must verify process chemistry, 汚染物質, プレッシャー, 温度, 速度, サイクリング, emissions and regulatory requirements.
品質, testing and traceability
Heat-number traceability and EN 10204 3.1 records matched to the ordered component specifications.
PMI, MTC, heat treatment records and specified ferrite, ASTM A923 or corrosion testing according to the project material specification.
API 598 or project-specified shell and closure testing, with acceptance and leakage criteria stated on the order.
GA drawing, 寸法, マーキング, operation, pressure test and specified NDE/third-party records.
見積依頼チェックリスト
- Valve design standard and required edition
- Nominal size and ASME Class or PN rating
- Exact material specifications for pressure boundary, trim, seats, packing and bolting
- Minimum/normal/maximum flow, fluid properties, line orientation and pump/system transient data
- End connection, facing and face-to-face requirement
- Fluid composition, 集中, contaminants and solids
- Design and operating pressure/temperature
- PMI, corrosion testing, 臨死体験, witnessing and document requirements
よくある質問
What is the difference between S31803 and S32205?
S32205 has tighter minimum alloying requirements that improve consistency of corrosion performance. Both are used for 2205 products, but the exact UNS grade must be stated.
Why is heat treatment important for duplex valves?
Correct solution heat treatment helps establish the required ferrite-austenite balance and dissolve harmful phases. Improper thermal history can reduce toughness and corrosion resistance.
Which tests are commonly requested for duplex material?
Projects may require PMI, ferrite measurement, ASTM A923 テスト, corrosion testing, impact testing and NDE. Requirements depend on product form, service and project specification.
What causes swing check valve slam?
Oversizing, low velocity, excessive disc travel and rapid flow reversal can cause impact closure. Correct hydraulic sizing and transient review are essential.
Can a swing check valve be installed vertically?
Only when approved for vertical upward flow and the operating velocity can open and stabilize the disc. Follow the qualified design and installation instructions.
Can Duplex 2205 be used for every component in this swing check valve?
Not automatically. Pressure-boundary, trim, stem or shaft, seating, packing, gasket and bolting materials have different mechanical and corrosion duties. The complete bill of materials must be engineered for the service.
Related Duplex 2205 valve products
Need a broader comparison? View the general stainless steel and alloy check valves guide or browse all 逆止弁.
Request a Duplex 2205 Swing Check Valve quotation
Send the valve specification, exact material grades, サイズ, 圧力クラス, operating conditions, 技術審査のための数量と検査要件.