Description
High-strength structural anchoring
ASTM F1554 Grade 105 Anchor Bolts
Factory-direct supply of common Grade 105 anchor rods and anchor-bolt assemblies. Quotations are checked against the ordered standard edition, drawing, thread, finish, nuts, washers and documentation.
Product scope and supply options
ASTM F1554 Grade 105 is the high-strength grade in the F1554 anchor-bolt specification. ASTM F1554 covers straight and bent, headed and headless anchor bolts, including all-thread rod used to anchor structural supports to concrete foundations. Grade 105 has a specified minimum yield strength of 105 ksi; the complete requirements come from the edition identified on the purchase order.
We supply common market anchor-rod and anchor-bolt configurations after checking the project drawing. Straight double-end rods, fully threaded rods, headed anchors, headless anchors, nuts, washers and plates can be reviewed as one supply package. Because high-strength material, heat treatment, diameter, thread and anchorage detail interact, unusual bends or fabricated assemblies are confirmed individually rather than assumed from a catalogue image.
Procurement specification
| Product | ASTM F1554 Grade 105 anchor bolts, anchor rods and matching assembly components |
|---|---|
| Material condition | Heat-treated medium-carbon alloy-steel product meeting the ordered Grade 105 requirements |
| Strength level | 105 ksi minimum specified yield strength; 125–150 ksi specified tensile-strength range |
| Standard diameter range | Nominal 1/2 in. through 3 in. for Grade 105 under ASTM F1554; exact availability and the ordered edition are confirmed during quotation |
| Common configurations | Straight anchor rod, double-end threaded rod, all-thread anchor rod, headed anchor bolt and headless assembly; other geometry requires drawing review |
| Threads | Thread series, class, pitch, threaded length, end configuration and allowance for coating must be stated or confirmed on the drawing |
| Finish | Plain or zinc-coated supply when specified; coated length, thread fit and matching hardware are reviewed as one system |
| Accessories | Compatible nuts, hardened washers, plates and templates can be quoted when the grade, dimensions, finish and quantity are stated |
| Inspection | Dimensional inspection, material traceability, mechanical-test documentation, marking review, coating records or third-party inspection as specified |
| Packaging | Common market and export packaging options selected according to size, finish, assembly condition and transport requirements |
| Delivery | Confirmed for each order; the fastest lead time can be 7 working days after technical and commercial approval |
Dimensions and drawing information
Diameter alone is not enough to manufacture or quote an anchor bolt. Provide the overall length, exposed projection, embedment length, threaded lengths, thread series and class, end chamfer, head or plate detail, coating scope and installation assembly. For headed bolts, the drawing should state the required head form and the measurement reference. For double-end rods, identify the top and bottom thread lengths separately.
If the project uses a plate, template or multiple nuts and washers, include those items on the same drawing. This helps control nut engagement, washer position, coating compatibility and packaging. For a fabricated anchorage system, the structural engineer remains responsible for the connection design, embedment and concrete performance; our quotation confirms the supplied metal components and stated inspection scope.
Grade 105 compared with Grades 36 and 55
| Grade 36 | 36 ksi minimum yield-strength grade, generally selected where the project specifies the lower-strength F1554 option. It is not interchangeable with Grade 105 without engineering approval. |
|---|---|
| Grade 55 | 55 ksi minimum yield-strength grade. ASTM F1554 includes a supplementary weldable-steel requirement for Grade 55 when specifically ordered. |
| Grade 105 | 105 ksi minimum yield-strength grade for high-strength anchor applications. It uses a different material and heat-treatment route and should not be field welded or substituted solely by matching dimensions. |
The grade number is a strength designation, not a complete product description. Selection must follow the project specification and engineer-approved design. A larger diameter in a lower grade is not automatically equivalent to a smaller Grade 105 anchor, and a visually similar threaded rod is not evidence of F1554 compliance.
Applications and selection checks
Structural columns
Anchor rods for column base plates where the structural design calls for the Grade 105 strength level.
Sign and lighting supports
Highway signs, lighting poles and traffic-signal supports when the governing drawing specifies Grade 105.
Equipment and bearing plates
Foundation connections requiring high-strength rods, plates, nuts and washers supplied to an approved assembly detail.
Infrastructure foundations
Project-specific bridge, utility or industrial anchorage where material, impact properties, coating and traceability are clearly specified.
Before ordering, confirm that Grade 105 is named in the design documents and that the specified diameter is within the governing standard range. Review service temperature, coating environment, tightening method, installation clearances, replacement restrictions and inspection requirements. Impact testing or permanent identification may be requested through supplementary requirements when the project specification calls for them.
Hardware, finish and documentation
Nuts and washers should be selected as compatible components rather than added after the anchor rods are made. State the required nut standard and grade, washer standard, quantity per bolt and finish. For coated assemblies, thread fit and coating allowances must be coordinated so that the nut can be installed without uncontrolled reworking.
Available order documentation can include the material test report, heat or lot traceability, mechanical-property results, dimensional inspection, coating report, marking check and third-party inspection when agreed. These documents are supplied only when included in the quotation or purchase order. A product photograph, colour mark or catalogue title does not replace the required certificates and inspection evidence.
Confirm geometry, threads, hardware and coating.
Confirm Grade 105 material, heat treatment and ordered edition.
Agree tests, documents, marking and witnessing.
Protect threads, finish and traceability for shipment.
RFQ checklist
- ASTM F1554 Grade 105 and the required standard edition
- Anchor type: straight, headed, headless, all-thread or double-end threaded
- Diameter, overall length, thread series, class and threaded length at each end
- Head, plate, template, projection and embedment details from the drawing
- Nut and washer standards, grades, quantities and assembly condition
- Plain or zinc-coated finish, coated length and required surface preparation
- Marking, traceability, test report, impact test and inspection requirements
- Quantity, packaging preference, destination and requested delivery date
Frequently asked questions
What does Grade 105 mean in ASTM F1554?
It is the F1554 grade with a specified minimum yield strength of 105 ksi. The ordered standard edition and complete product description govern all material, testing, dimensional and acceptance requirements.
What is the common diameter range for F1554 Grade 105?
The standard Grade 105 range is nominal 1/2 in. through 3 in. Confirm the exact diameter, ordered edition, length and thread requirements during quotation.
Can ASTM F1554 Grade 105 anchor bolts be galvanized?
Zinc-coated supply can be reviewed when it is specified. The coating process, coated length, thread fit and compatible nuts and washers must be confirmed together.
Can Grade 105 anchor bolts be welded?
Welding should not be assumed. Grade 105 is heat treated, and uncontrolled welding or heating can affect its properties. Refer any welded detail to the project engineer and an approved procedure before fabrication or installation.
What information is needed for a quotation?
Send the drawing, grade and standard edition, diameter, length, thread details, configuration, finish, nuts, washers, documentation, quantity, destination and required date.
Request an ASTM F1554 Grade 105 quotation
Send your drawing and procurement requirements. We will confirm the available configuration, documentation, packaging and order-specific lead time.