ASTM A182 F60 Orifice Flange RFQ Checklist
Quick Answer
An ASTM A182 F60 orifice flange RFQ should identify the material grade, ASME B16.36 edition, flange type, NPS, pressure class, facing, pipe schedule or bore, pressure-tap arrangement, tap thread, orientation, jack screws, plugs, companion plate and gasket scope, inspection requirements and document package. F60 defines the duplex forging material; it does not by itself define the flange dimensions, tap details or complete flow-measurement assembly.
Use the checklist below to convert a general “F60 duplex flange” request into a reviewable orifice-flange inquiry. For the matching product route, see the ASTM A182 F60 Duplex 2205 orifice flange.
Separate the Material, Flange and Metering Decisions
Three documents can control different parts of the purchase. ASTM A182/A182M covers forged or rolled alloy and stainless steel flanges and related forged components within its scope; F60 is associated with UNS S32205 duplex stainless steel. ASME B16.36 covers orifice flanges with pressure-differential connections, including ratings, dimensions, tolerances, testing and marking within its stated scope. The project flow-measurement specification then defines the complete metering arrangement, plate data, tap interface and installation requirements.
Do not replace these separate decisions with “Duplex 2205, standard size.” The RFQ should state each governing document and edition. If the buyer has not yet frozen F51 versus F60, review the F51 versus F60 flange comparison before quotation.
F60 Orifice Flange RFQ Matrix
| RFQ field | What to state | Why it matters |
|---|---|---|
| Material | ASTM A182/A182M edition, F60 / UNS S32205, supplementary requirements if applicable | Locks the forging grade and purchaser-added requirements |
| Flange standard | ASME B16.36 edition, flange type, NPS and class | Defines the orifice-flange configuration and dimensional basis |
| Pipe interface | Pipe OD, schedule or actual bore, weld-end requirement | Prevents a bore or weld-end mismatch at fit-up |
| Facing and plate | RF or RTJ, facing finish, plate and gasket scope | Controls the sealing and plate interface |
| Pressure taps | Tap arrangement, quantity, thread, orientation and plugging | Aligns the flange with impulse piping and transmitter layout |
| Assembly details | Matched pair, jack screws, bolts/nuts and accessories included | Makes quotation scope comparable between suppliers |
| Inspection and records | Dimensions, PMI/NDE/test scope, ITP, MTC and final dossier | Creates traceable acceptance evidence |
Confirm That the Requested Type Is Inside the Standard Scope
The current ASME description of B16.36 covers welding-neck orifice flanges in Classes 300, 400, 600, 900, 1500 and 2500, and slip-on or threaded orifice flanges in Class 300. A buyer should therefore state the flange type, size and class instead of assuming every standard flange combination is available as an ASME B16.36 orifice flange.
Scope check: If the project requests a configuration outside the published standard scope, identify it as a project-specific design and require drawing, design and approval responsibilities to be stated. Do not label it compliant by resemblance alone.
Freeze the Tap and Instrument Interface
“With taps” is incomplete. State the required tap arrangement, the number of taps, the thread or connection standard, circumferential orientation, plug requirements and which side connects to the high- and low-pressure impulse lines. The transmitter location and piping layout can affect the preferred orientation.
The article Orifice Flange Tap Types: Flange Taps vs Corner Taps vs D-D/2 explains the measurement locations. This checklist addresses the separate procurement question: which interface details must appear in the RFQ and approved drawing.
Control the Bore, Facing and Matched-Pair Details
- Bore: provide pipe schedule or actual bore and require it to be shown on the drawing.
- Facing: state RF or RTJ and the project-required surface finish or groove designation.
- Plate interface: state whether the plate, plate carrier, gaskets and bolting are included or supplied separately.
- Matched pair: require upstream and downstream components to be identified consistently when the project treats them as a set.
- Jack screws and plugs: define quantity, material and inclusion so the quotation does not omit required accessories.
Inspection and Document Hold Points
| Stage | Buyer check | Record |
|---|---|---|
| Drawing review | Type, class, bore, facing, taps, orientation and accessories match the RFQ | Approved drawing and deviation register |
| Material identity | Grade and heat traceability match the order | MTC and traceability list |
| Dimensional inspection | Critical flange, bore, facing and tap features checked to the approved basis | Dimensional report |
| Final release | Marking, plugs, jack screws, pairing and preservation complete | Release note, packing list and dossier index |
Testing and inspection are purchase-specific. Do not infer PMI, NDE, corrosion testing, ferrite measurement or third-party inspection from the grade name alone. List required methods, sampling, acceptance criteria and witness or hold points in the inquiry. For certificate review fields, use the separate ASTM A182 flange MTC buyer checklist.
Common RFQ Errors
- Writing “F60 flange” without the dimensional standard, type, size and class.
- Naming B16.36 but omitting the adopted edition and project exceptions.
- Leaving bore or pipe schedule unresolved until fabrication.
- Assuming the orifice plate, gaskets, bolting, taps, plugs and jack screws are all included.
- Requesting “full testing” without methods, sampling or acceptance criteria.
- Approving a drawing without checking tap orientation against the instrument layout.
Frequently Asked Questions
Does ASTM A182 F60 define an orifice flange?
No. F60 identifies the forged duplex material grade. The orifice-flange configuration must be specified separately, commonly by ASME B16.36 plus the project measurement requirements.
Can every pressure class use a slip-on F60 orifice flange?
Do not assume so. The published B16.36 scope lists slip-on and threaded orifice flanges for Class 300, while welding-neck coverage includes the stated higher classes. Confirm the adopted edition and project requirements.
Should the RFQ include the orifice plate?
It should clearly state whether the plate and its data are included, supplied by another party or excluded. The flange quotation should not leave this interface ambiguous.
Is F60 the same as every Duplex 2205 designation?
Use the exact ordered specification and grade. ASTM A182 F60 is associated with UNS S32205; commercial “2205” wording alone is not a complete purchase designation.
Reference basis: ASTM A182/A182M-26, ASME B16.36-2025 and Alleima Sanmac 2205 material data. Use the editions and requirements specified by the purchase order or project; this checklist does not replace the controlled standards or engineering approval.
Send a Complete F60 Orifice Flange RFQ