Descripción
Super duplex stainless steel industrial valve
Súper Dúplex 2507 Válvula de compuerta de cuña
A severe chloride-service valve material for seawater, costa afuera, desalination and aggressive process systems. The wedge gate valve configuration is engineered for fully open or fully closed isolation with low open-position pressure loss.
What is a Super Duplex 2507 Válvula de compuerta de cuña?
A Super Duplex 2507 Wedge Gate Valve combines a highly alloyed ferritic-austenitic stainless steel with high strength and strong resistance to chloride pitting, crevice corrosion and stress-corrosion cracking with a full-opening linear isolation design that raises a wedge out of a substantially straight flow path.
2507 requires disciplined material procurement, forming, soldadura, heat treatment and testing to preserve phase balance and corrosion performance. A wedge gate valve is not normally used for throttling because partial opening can produce vibration and seat or guide damage.
Súper Dúplex 2507 Wedge Gate Valve specifications
| Producto | Súper Dúplex 2507 Válvula de compuerta de cuña |
|---|---|
| Construcción de válvulas | Bolted-bonnet outside-screw-and-yoke rising-stem gate valve with flexible or solid wedge |
| Material nominal | Súper Dúplex 2507 |
| A NOSOTROS / una referencia | UNS S32750; EN 1.4410 |
| Formularios de productos | Forjado ASTM A182 F53; project-approved ASTM A995/A890 cast grade selected by chemistry and properties; exact component specification required |
| Estándares de diseño | API 600 y ASME B16.34; API 602 for applicable compact forged designs |
| Prueba de presión | API 598 or project-specified shell, backseat and closure testing |
| Clasificación de presión | Clase ASME o clasificación PN verificada con el material exacto, tamaño, temperatura de construcción y diseño |
| Conexiones finales | Extremos RF/RTJ bridados o soldados a tope según diseño |
| Operación | Handwheel, gearbox, electric, pneumatic or hydraulic actuator |
| Documentación | EN 10204 3.1 registros de materiales, informe de prueba de presión, Registros de inspección del proyecto y planos GA según lo ordenado |
Este es un producto de consulta diseñado, no es una especificación de stock universal. La disponibilidad final depende del tamaño de la válvula., clase de presión, forma material, recortar, sistema de asiento, operador, cantidad y edición del código requerido.
Súper Dúplex 2507 selección de materiales
| Punto de selección | Orientación de ingeniería |
|---|---|
| perfil de material | a highly alloyed ferritic-austenitic stainless steel with high strength and strong resistance to chloride pitting, crevice corrosion and stress-corrosion cracking |
| Por qué se selecciona | High strength and high resistance to localized chloride corrosion when correctly manufactured and specified. |
| Servicio tipico | Seawater injection, desalinización, costa afuera, brine and aggressive chloride-bearing process systems. |
| Limitaciones a comprobar | Upper and lower service-temperature limits, hydrogen exposure, galvanic coupling and intermetallic precipitation require engineering review. |
| Ruta de especificación | Forjado ASTM A182 F53; project-approved ASTM A995/A890 cast grade selected by chemistry and properties; exact component specification required |
| Verificación | 100 percent PMI where ordered, MTC and heat treatment review, ferrite testing plus specified ASTM A923, corrosión, impact and NDE requirements. |
Wedge Gate Valve design and standards
API 600
Common design basis for bolted-bonnet steel gate valves, including material, recortar, testing and marking requirements.
ASME B16.34
General pressure-temperature and valve design requirements within scope.
API 598
Shell, backseat and closure pressure testing when specified.
API 624 / ISO 15848-1
Fugitive-emission qualification is specific to the packing system and qualified valve design.
Wedge flexibility, seat hardfacing, stem/packing system, body cavity drainage, thermal binding risk and operating thrust require service-specific review.
A prueba de fuego, emisión-fugitiva, servicio amargo, oxígeno, criogénico, Los requisitos de cloro y PED se aplican solo cuando se definen y admiten explícitamente para la configuración ofrecida exacta..
Aplicaciones típicas
| Industria | Contexto de servicio material | Enfoque en la selección de válvulas |
|---|---|---|
| Petróleo y gas marinos | Seawater injection, firewater and chloride-rich process systems | Full-open isolation, wedge/seat materials, thermal effects, packing emissions and operator thrust |
| Desalination | High-chloride feed, brine and reverse-osmosis support systems | Full-open isolation, wedge/seat materials, thermal effects, packing emissions and operator thrust |
| Procesamiento químico | Aggressive chloride and acidic streams after compatibility review | Full-open isolation, wedge/seat materials, thermal effects, packing emissions and operator thrust |
| ingeniería marina | Seawater cooling and critical marine utility systems | Full-open isolation, wedge/seat materials, thermal effects, packing emissions and operator thrust |
Los ejemplos de aplicación no constituyen una aprobación de corrosión o de diseño.. El usuario final debe verificar la química del proceso., contaminantes, presión, temperatura, velocidad, ciclismo, emisiones y requisitos reglamentarios.
Calidad, pruebas y trazabilidad
Trazabilidad del número de calor y EN 10204 3.1 registros coincidentes con las especificaciones del componente solicitado.
100 percent PMI where ordered, MTC and heat treatment review, ferrite testing plus specified ASTM A923, corrosión, impact and NDE requirements.
API 598 or project-specified shell, backseat and closure testing, con criterios de aceptación y fugas indicados en el pedido.
dibujo de ga, dimensiones, calificación, operación, prueba de presión y registros de NDE/terceros especificados.
Lista de verificación de solicitudes de presupuesto
- Estándar de diseño de válvula y edición requerida.
- Tamaño nominal y clasificación ASME Class o PN
- Especificaciones exactas del material para el límite de presión., recortar, asientos, embalaje y atornillado
- Flexible or solid wedge, seat/hardfacing, stem arrangement, packing and operator requirements
- Finalizar conexión, requisito presencial y presencial
- Composición fluida, concentración, contaminantes y sólidos
- Presión/temperatura de diseño y funcionamiento
- PMI, prueba de corrosión, ECM, requisitos de testimonios y documentos
Preguntas frecuentes
How is super duplex 2507 different from duplex 2205?
2507 contains higher chromium, molybdenum and nitrogen and generally offers greater strength and localized-corrosion resistance. It also requires tighter fabrication and heat-treatment control.
Es 2507 automatically suitable for all seawater service?
No. Temperature, cloración, grietas, depósitos, fluir, galvanic couples and cathodic protection affect performance. The complete system must be reviewed.
What documentation should be requested?
Common requirements include EN 10204 3.1 records, PMI, heat-treatment evidence, ferrite results and specified corrosion, impact and NDE reports.
Can a wedge gate valve be used for throttling?
Normally no. It is intended for fully open or fully closed service; extended partial opening can damage the wedge, seats and guides.
What is the difference between flexible and solid wedges?
A flexible wedge can accommodate limited alignment and thermal effects, while a solid wedge is more rigid. Selection follows the design and service conditions.
Can Super Duplex 2507 be used for every component in this wedge gate valve?
No automáticamente. Límite de presión, recortar, vástago o eje, asientos, embalaje, Los materiales de juntas y pernos tienen diferentes funciones mecánicas y de corrosión.. La lista completa de materiales debe estar diseñada para el servicio..
Related Super Duplex 2507 productos de válvulas
Necesita una comparación más amplia? Ver el general stainless steel and alloy gate valves guide o navegar por todos Válvulas de compuerta.
Request a Super Duplex 2507 Wedge Gate Valve quotation
Enviar la especificación de la válvula., grados exactos de materiales, tamaño, clase de presión, condiciones de funcionamiento, requisitos de cantidad e inspección para la revisión técnica.